Here are some examples of using the redirection to non-DOS drive resources feature in LANtastic 5.0. They are intended to give you a basic outline for setting up the resources. Novell/LANtastic Connectivity with NOS 5.0 Double Redirections with Netware (Note: We don't use LANtastic for Netware in this example, because a workstation would have access to the Netware server directly) Our testing was performed with the following equipment: 1 NodeRunner adapter (For Netware) Settings: NE2000 Mode IRQ=3 IOBASE=300 1 NodeRunner adapter (For LANtastic) Settings: Artisoft Mode IRQ=10 IOBASE=340 Compuadd 386sx 16 with 4Meg of ram, 40 Meg Harddisk Here are the steps necessary to setup the connection: 1) Install two network adapters in a machine. Make sure each adapter is using a serparte irq and iobase. 2) Setup an AUTOEXEC.BAT to load both sets of network drivers. The AUTOEXEC will differ if you are using IPX drivers as opposed to ODI drivers. In addition, a NET.CFG file must be included if you are using ODI drivers. CONFIG.SYS device=c:\dos\himem.sys ; Extended Memory drive dos=high ; Load dos high files=200 buffers=32 fcbs=16,8 lastdrive=j IPX AUTOEXEC.BAT prompt $p$g path c:\dos;c:\netware;c:\lantasti; ipx ; Novell IPX Driver noderun iobase=340 ; Noderunner LANtastic Driver ailanbio ; LANtastic NetBIOS Driver redir cube logins=3 ; LANtastic Redirector server ; LANtastic Server netx ; Novell Network shell ODI AUTOEXEC.BAT prompt $p$g path c:\dos;c:\netware;c:\lantasti; lsl ; Novell Link Support Layer driver nrodi ; Noderunner ODI Driver ipxodi ; Novell ODI IPX driver noderun iobase=340 ; Noderunner LANtastic Driver ailanbio ; LANtastic NetBIOS Driver redir cube logins=3 ; LANtastic Redirector server ; LANtastic Server netx ; Novell Network shell ODI NET.CFG link driver nrodi frame ETHERNET_802.3 3) Set Lastdrive for Netware Change your CONFIG.SYS so that LASTDRIVE=J, Netware will use K: for the login drive. 4) Set up the Netware resource Run NET_MGR. Choose SHARED RESOURCES MANAGMENT. Press INSERT. Type in NOVELL for the resource name. Put in K: (or the drive letter of the mapped drive you wish to share) for the path to the drive. Then select the NOVELL resource. Select DISK DRIVE TYPE and choose Netware. Press ESCAPE until you return to DOS. 5) Reboot the machine. After the machine comes back up, users should be able to log into the server and use the Novell resource to access the Novell server. Unix/LANtastic Connectivity with NOS 5.0 Double Redirections with Unix Our testing was performed with the following equipment: 1 Sun Interactive Unix Server (System V Release 3.2 Version 3.0.1) TCP/IP and NFS Installed Magitronics 386 33 8 meg of Ram 200 Meg Had drive AE3 adapter Settings: NE2000 Mode IRQ=5 IOBASE=300 1 LANtastic Server V5.0, DOS 6.0 Compuadd 386sx 25 with 8Meg of ram, 130 Meg Harddisk NodeRunner adapter Settings: Artisoft Mode IRQ=15 IOBASE=300 1 LANtastic Workstation V5.0, DOS 5.0 Compuadd 386sx 25 with 4Meg of ram, 120 Meg Harddisk NodeRunner adapter Settings: Artisoft Mode IRQ=15 IOBASE=300 NDIS Support for LANtastic LANtastic for TCP/IP Here are the steps necessary to setup of the connection: 1) Setup LANtastic software on server The Server machine must have LANtastic V5.0 and LANtastic for TCP/IP installed and properly configured. NDIS Support for LANtastic is optional, but is used in this example. 2) Setup a CONFIG.SYS and AUTOEXEC.BAT to load the network drivers. In addition, a PROTOCOL.INI is required for NDIS. Here are the files used in this example. CONFIG.SYS device=c:\dos\himem.sys ; Dos extended memory driver dos=high ; Load DOS high device=c:\ndis\protman.dos /i:c:\ndis ; Load NDIS Protocol Manager device=c:\ndis\aexndis.dos ; Load the NDIS Mac layer or card driver files=200 buffers=32 stacks=9,256 fcbs=16,8 lastdrive=z AUTOEXEC.BAT path c:\dos;c:\ndis;c:\lantasti;c:\lantcp; share /f:2048 /l:200 wgndis -D:2 ; Load LANtastic TCP/IP ; driver for NDIS ai-ndis bind_to=aexndis verbose ; Load LANtastic Netbios ; driver for NDIS ailanbio ; Load LANtastic Netbios redir mikew buffers=2 verbose ; Load LANtastic Redirector server ; Load LANtastic Server ARTiTCP ; Load LANtastic TCP/IP ; Configuration File ASTCP ; Load LANtastic TCP/IP ; Kernal nfs ; Load NFS client driver mount e: \\tiny1\/usr2 username password ; Redirect NFS drive to ; Unix Host NDIS PROTOCOL.INI [PROTOCOL MANAGER] Drivername=PROTMAN$ Dynamic=yes [AEXNDIS] Drivername=AEXNDS$ ; Identify Mac driver for Noderunner Interrupt=15 ; Set card IRQ=15 IObase=0x300 ; Set IOBase=300 3) Set up the Unix resource Run NET_MGR. Choose SHARED RESOURCES MANAGMENT. Press INSERT. Type in UNIX for the resource name. Put in E: (or the drive letter of the mapped drive you wish to share) for the path to the drive. Then select the UNIX resource. Select DISK DRIVE TYPE and choose OTHER. Press ESCAPE until you return to DOS. 4) Reboot the machine. After the machine comes back up, users should be able to log into the server and use the UNIX resource to access the Unix server.