Technical Support Note Product(s) involve : QCD Version 1.0 Third party product(s) : Hi-Color SVGA cards Subject "Application Error, QCD caused a General Protection Fault in module XXXXXXXX.DRV at YYYY:ZZZZ" Description User may encounter the above-mentioned error message when executing QCD version 1.0 with Windows 3.1 display configured to run Hi-color mode (eg. 16K, 32K, 64K, 16.7M colors). The module XXXXXXXX.DRV refers to the VGA driver and YYYY:ZZZZ represents the location when the fault occurs. Solution/Action This problem can be solved by a newer version of QCD (version 1.10), the new QCD be located in SB-BBS: File Name : QCD_WU.ZIP File Size : 43903 bytes Location : Distributor conference Common file area - 1 The unzipped contents should be as follows: File Name : QCD.EXE CTCCW.DLL File Size : 64832 bytes 32336 bytes Date : 07-06-93 07-06-93 Time : 01:10 hrs 02:20 hrs All distributors and users are advised to download this file and update all ealier version of QCD and related DLL accordingly.