TITLE: 104XX ESDI DRIVES AND ADAPTERS ERRORS...............1026 10440 8550-021 60 Meg ESDI Adapter Error. 10441 8550-021 60 Meg ESDI Adapter Error. 10442 8550-021 60 Meg ESDI Adapter Error. 10443 8550-021 60 Meg ESDI Adapter Error. 10444 8550-021 60 Meg ESDI Adapter Error. 10445 8550-021 60 Meg ESDI Adapter Error. 10446 8550-021 60 Meg ESDI Adapter Error. 10447 8550-021 60 Meg ESDI Adapter Error. 10450 DIAGS Error - Replace drive (read write test failed) 10451 DIAGS Error - Replace drive (read verify test failed) 10452 DIAGS Error - Replace drive (seek test failed) 10453 DIAGS Error - Replace drive (wrong drive type indicated) 10454 DIAGS Error - Controller (controller test failed sector buffer test) 10455 DIAGS Error - Controller (controller failure, invalid failure) 10456 DIAGS Error - Controller (diag command failure) 10457 DIAGS Error - Repl. drive (integrated controller test failure) 10458 DIAGS Error - Repl. drive (integrated controller test failure) 10458 DIAGS Error - If 8570-121 or 8570-A21 see ECA020 10459 DIAGS Error - Replace drive (diag command failure) 10460 DIAGS Error - Unknown. Repl. drive, then controller, then system board 10461 DIAGS Error - Drive fromat error 10462 DIAGS Error - Controller (head select error) 10463 DIAGS Error - Drive (read/write sector error) 10464 DIAGS Error - Drive (primary map unreadable) 10465 DIAGS Error - Controller (ECC 8 bit error) 10466 DIAGS Error - Controller (ECC 9 bit error) 10467 DIAGS Error - Drive (soft seek error) 10468 DIAGS Error - Drive (hard seek error) 10469 DIAGS Error - Drive (drive soft error count execeeded) 10470 DIAGS Error - Controller (attachment diag error) 10471 DIAGS Error - Controller (wrap mode interface error) 10472 DIAGS Error - Controller (wrap mode drive selected error) 10473 DIAGS Error - Unknown. Repl. drive, then controller, then system board 10474 DIAGS Error - Unknown. Repl. drive, then controller, then system board 10475 DIAGS Error - Unknown. Repl. drive, then controller, then system board 10476 DIAGS Error - Unknown. Repl. drive, then controller, then system board 10477 DIAGS Error - Unknown. Repl. drive, then controller, then system board 10478 DIAGS Error - Unknown. Repl. drive, then controller, then system board 10479 DIAGS Error - Unknown. Repl. drive, then controller, then system board 10480 POST Error - Replace disk "C" (seek failure) 10480 DIAGS Error - Controller (com/data-attn bad) 10481 POST Error - Replace disk "D" (seek failure) 10481 DIAGS Error - Controller (xfr req-ready bad) 10482 POST Error - Replace controller (failed controller test) 10482 DIAGS Error - Controller (drvsell-xfr ack bad) 10483 POST Error - Replace controller (failed reset) 10483 POST Error - If 8570-121 or 8570-A21 see ECA020 10483 DIAGS Error - Controller (drvse10-config/stat bad) 10484 DIAGS Error - Controller (hdse13-selected bad) 10485 DIAGS Error - Controller (hdse12-selected bad) 10486 DIAGS Error - Controller (hdse11-selected bad) 10487 DIAGS Error - Controller (hdse10-selected bad) 10488 DIAGS Error - Controller (rg - cmd cmplt 2) 10489 DIAGS Error - Controller (wg - cmd cmplt 1) 10490 POST Error - Replace disk "C" (read failure) 10490 DIAGS Error - Controller (drive connected no test done) 10491 POST Error - Replace disk "D" (read failure) 10499 DIAGS Error - Controller Failure ~~~~~