ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ» º º º Modem Standards º º º ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ INTRODUCTION TO MODEM SPECIFICATIONS Intel modems support three sets of standards: Bell, MNP, and CCITT. Bell standards define modem operations at various speeds. MNP defines several classes of error correction and data compression. CCITT standards define modem operations and error correction/data compression, as well as diagnostic tests and RS-232 specifications for external modems. Intel modems support the standards listed below. Any standards not listed are not supported. BELL STANDARDS Intel modems support these Bell specifications: ÚÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄ¿ ³CCP³Satis- ³2400B ³ ³2400B³2400EX³ ³ ³ ³ ³FAXtion³Classic³2400EX³MNP ³MNP ³9600EX³14.4EX³ ÕÍÍÍÍÍÍØÍÍÍØÍÍÍÍÍÍÍØÍÍÍÍÍÍÍØÍÍÍÍÍÍØÍÍÍÍÍØÍÍÍÍÍÍØÍÍÍÍÍÍØÍÍÍÍÍ͵ ³ 103 ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ ÃÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³ 212A ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ ÀÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÙ MNP STANDARDS Intel modems support these MNP specifications ÚÄÄÄÄÄÂÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄ¿ ³MNP ³CCP³Satis- ³2400B ³ ³2400B³2400EX³ ³ ³ ³Class³ ³FAXtion³Classic³2400EX³MNP ³MNP ³9600EX³14.4EX³ ÆÍÍÍÍÍØÍÍÍØÍÍÍÍÍÍÍØÍÍÍÍÍÍÍØÍÍÍÍÍÍØÍÍÍÍÍØÍÍÍÍÍÍØÍÍÍÍÍÍØÍÍÍÍÍ͵ ³ 1 ³ ³ * ³ ³ ³ * ³ * ³ * ³ * ³ ÃÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³ 2 ³ ³ * ³ ³ ³ * ³ * ³ * ³ * ³ ÃÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³ 3 ³ ³ * ³ ³ ³ * ³ * ³ * ³ * ³ ÃÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³ 4 ³ ³ * ³ ³ ³ * ³ * ³ * ³ * ³ ÃÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³ 5 ³ ³ * ³ ³ ³ * ³ * ³ * ³ * ³ ÀÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÙ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ November 8, 1991 Intel FaxBACK # 4302 Page 1 ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ» º º º Modem Standards º º º ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ (continued) ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ CCITT STANDARDS Intel modems support these CCITT specifications: ÚÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄ¿ ³CCP³Satis- ³2400B ³ ³2400B³2400EX³ ³ ³ ³ ³FAXtion³Classic³2400EX³MNP ³MNP ³9600EX³14.4EX³ ÕÍÍÍÍÍÍÍØÍÍÍØÍÍÍÍÍÍÍØÍÍÍÍÍÍÍØÍÍÍÍÍÍØÍÍÍÍÍØÍÍÍÍÍÍØÍÍÍÍÍÍØÍÍÍÍÍ͵ ³V.21 ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ ÃÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³V.22 ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ ÃÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³V.22A ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ ÃÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³V.22B ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ ÃÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³V.22bis³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ ÃÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³V.24 ³ ³ ³ ³ * ³ ³ * ³ * ³ * ³ ÃÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³V.32 ³ ³ ³ ³ ³ ³ ³ * ³ * ³ ÃÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³V.32bis³ ³ ³ ³ ³ ³ ³ ³ * ³ ÃÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³V.42 ³ ³ ³ ³ ³ ³ ³ * ³ * ³ ÃÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³V.42bis³ ³ ³ ³ ³ ³ ³ * ³ * ³ ÃÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄ´ ³V.54 ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ * ³ ÀÄÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÙ DEFINITIONS OF STANDARDS BELL STANDATDS Bell Standards 103 Defines 300 baud communications. Intel modems support this standard. 201C/ 201D Defines half-duplex, 2400 baud communications using Bell's proprietary protocol. Intel modems do not support these standards. 208 Defines 4800 baud communications using Bell's proprietary protocol. Modems supporting this standard are mainly used on older mainframe computers and rarely on personal computers. Intel modems do not support this standard. 212A Defines 1200 baud communications. Intel modems support this standard. ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ November 8, 1991 Intel FaxBACK # 4302 Page 2 ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ» º º º Modem Standards º º º ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ (continued) ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ MNP STANDARDS Class 1 Asynchronous, byte-oriented, half-duplex data exchange. About 70 percent efficient.* Rarely used in the U.S. Class 2 Asynchronous, byte-oriented, full-duplex data exchange. About 84 percent efficient. Class 3 Synchronous, bit-oriented, full-duplex data exchange. About 108 percent efficient. Class 4 Similar to Class 3 but adds Adaptive Packet Assembly and Data Phase Optimization. About 120 percent efficient. Class 5 Similar to Class 4 but adds Data Compression. About 200 percent efficient.** * Transmission efficiency is calculated by dividing Actual bps Throughput by Transmission bps Rate. ie... 1690bps / 2400bps = 70% ** Actual efficiency depends on the type of data transmitted. ASCII text files typically compress more than COM or EXE files and thus transmit with greater efficiency. For definitions of the technical terms used here, as well as other pertinent information, get "Dvorak's Guide to PC Telecommunications" available at many book stores. CCITT STANDARDS All specifications are for the general switched telephone networks, unless specified otherwise. Refer to the Supported Standards section for a list of the standards supported by Intel modems. V.21 300 bps duplex modem V.22 1200 bps duplex modem V.22bis 2400 bps duplex modem using the frequency division technique V.23 600/1200-Baud modem V.24 List of definitions for interchange circuits between data terminal equipment and data circuit-terminating equipment V.25 Automatic answering equipment and/or parallel automatic calling equipment standard including procedures for disabling of echo control devices for both manually and automatically established calls V.25bis Same as V.25, but using the 100-Series interchange circuits V.26 2400 bps modem for use on 4-wire leased telephone-type circuits V.26bis 2400/1200 bps modem V.26ter 2400 bps duplex modem using the echo cancellation technique (general switched phone networks & point-to- point 2-wire leased telephone-type circuits) ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ November 8, 1991 Intel FaxBACK # 4302 Page 3 ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ» º º º Modem Standards º º º ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ (continued) ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ V.27 4800 bps with manual equalizer for use on leased telephone-type circuits V.27bis 4800/2400 bps with automatic equalizer for use on leased telephone-type circuits V.27ter 4800/2400 bps modem V.28 Electrical characteristics for unbalanced double-current interchange circuits V.29 9600 bps modem for use on point-to-point 4-wire leased telephone-type circuits V.32 2-wire, duplex modems operating at data signalling rates of up to 9600 bps for general and leased line circuits V.32bis 2-wire, duplex modems operating at data signalling rates of up to 14400 bps for general and leased line circuits V.42 Error correction scheme (called LAPM) with MNP-4 fall- back V.42bis Data compression techniques superior to that of MNP-5 V.54 Loop test devices/methods for modems ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ November 8, 1991 Intel FaxBACK # 4302 Page 4