A/ REPEAT COMMAND A: CONTINUOUS REDIAL A ANSWER FORCED B0 CCITT MODE B1 BELL MODE D DIAL DN STORE PHONE NUMBER (N0-N9) E0 ECHO OFF E1 ECHO ON &F FACTORY DEFAULTS H0 HANG UP H1 HOOK OFF I0 MODEM MODEL I1 MODEM REVISION L LIST PHONE NUMBERS L5 LIST CURRENT PARAMETERS L6 LIST CURRENT S-REGISTERS L7 LIST ADDITIONAL PARAMETERS HIT ANY KEY TO CONTINUE M0 SPEAKER OFF M1 SPEAKER ON UNTIL CONNECTION M2 SPEAKER ON N DIAL PHONE NUMBER (N0-N9) O RETURN TO ONLINE P PULSE DIAL Q0 RESPONSES ON Q1 RESPONSES OFF Q2 RESPONSES OFF IN ANSWER MODE R REVERSE TO ANSWER MODE AFTER DIALING R0 REVERSE MODE OFF R1 REVERSE MODE ON S0= SET S-REGISTERS (S0-S30) S0? READ S-REGISTERS T TONE DIAL U0 ANALOG LOOP (ORIGINATE) U1 ANALOG LOOP (ANSWER) U2 REMOTE DIGITAL LOOP BACK U3 DIGITAL LOOP BACK HIT ANY KEY TO CONTINUE V0 TERSE RESULT CODES V1 VERBOSE RESULT CODES W WAIT FOR 2ND DIALTONE X0 BASIC RESULT CODES (CONNECT) X1 EXTENDED RESULT CODES (CONNECT 9600) X2 X1 WITH ENABLE DIALTONE DETECT X3 X1 WITH ENABLE BUSY DETECT X4 COMBINE X1,X2,X3 Y0 LONG SPACE DISCONNECT OFF Y1 LONG SPACE DISCONNECT ON Z RESET MODEM : CONTINUOUS REDIAL / PAUSE 125 MS , PAUSE, EQUALS S6 VALUE ; RETURN TO COMMAND MODE AFTER DIALING ! FLASH HOOK @ QUIET ANSWER HIT ANY KEY TO CONTINUE &E0 NORMAL MODE &E1 AUTO-RELIABLE MODE &E2 RELIABLE MODE &E3 FLOW CONTROL OFF &E4 CTS/RTS FLOW CONTROL &E5 XON/XOFF FLOW CONTROL &E6 XON/XOFF PASS THRU OFF &E7 XON/XOFF PASS THRU ON &E8 ENQ/ACK OFF &E9 ENQ/ACK ON &E10 NORMAL MODE FLOW CONTROL OFF &E11 NORMAL MODE FLOW CONTROL ON &E12 PACING OFF &E13 PACING ON &E14 COMPRESSION OFF &E15 COMPRESSION ON HIT ANY KEY TO CONTINUE $BA0 BAUD ADJUST OFF (SPEED CONVERSION ON) $BA1 BAUD ADJUST ON $MB MODEM BAUD RATE $MI MI/MIC OPTION $SB SERIAL BAUD RATE &W0 STORE PARAMETERS TO MEMORY &W1 PARAMETERS NOT STORED TO MEMORY B1 E0 M1 Q0 R0 V1 X1 &E1 &E4 &E7 &E8 &E10 &E13 &E15 $MB14400 $SB38400 $BA0 &W0 OK $A0 AUTO-RELIABLE BUFFERING DURING LINKING OFF $A1 AUTO-RELIABLE BUFFERING DURING LINKING ON &A0 ANSWERBACK OFF &A1 ANSWERBACK ON &B0 STANDARD TRANSMIT BUFFER SIZE (2K) &B1 REDUCED BUFFER SIZE (512) &BS0 MAX TRANSMIT BLOCK SIZE (64 CHAR.) &BS1 MAX TRANSMIT BLOCK SIZE (256 CHAR.) &C0 DCD FORCED &C1 DCD NORMAL &C2 DCD ON UNTIL DISCONNECT, FOLLOWS (S24) $D0 DTR DIALING OFF $D1 DTR DIALING ON &D0 DTR IGNORED &D1 RETURN TO COMMAND MODE &D2 DTR NORMAL &D3 DROP OF DTR CAUSES MODEM TO RESET $F0 LINK FALLBACK OFF $F1 LINK FALLBACK ON HIT ANY KEY TO CONTINUE &G0 GUARD TONES OFF &G1 GUARD TONE 550 HZ (INTERNATIONAL) &G2 GUARD TONE 1800 HZ (INTERNATIONAL) &M0 ASYNC MODE &M1 SYNC MODE WHEN ON-LINE &P0 PULSE DIAL RATIO 60/40 &P1 PULSE DIAL RATIO 67/33 &Q0 ENABLE RELIABLE AND COMPRESSED RESPONSES &Q1 SUPRESS RELIABLE AND COMPRESSED RESPONSES &Q2 ORIGINAL MULTI-TECH RESPONSES (&Q0,&Q2) &Q3 ENHANCED MULTI-TECH RESPONSES (&Q0,&Q3) $R0 DISCONNECT AFTER 12 RETRANSMITS IN RELIABLE MODE $R1 UNLIMITED RETRANSMITS IN RELIABLE MODE &R0 CTS NORMAL &R1 CTS FORCED ON IN COMMAND MODE &R2 CTS FORCED ON UNTIL DISCONNECT, FOLLOWS (S24) &S0 DSR FORCED ON &S1 DSR NORMAL &S2 DSR FORCED ON UNTIL DISCONNECT, FOLLOWS (S24) &T4 RDLB ENABLED &T5 RDLB DISABLED HIT ANY KEY TO CONTINUE #A0 DETECT ALL SPEEDS DURING HANDSHAKE,(96,48,24,12,3) #A1 DISABLE DETECTION OF 4800, (96,24,12,3) #A2 DETECT V.32 MODE ONLY (96,48) #A3 DISABLE V.32 DETECT (24,12,3) #DB0 CALLBACK OFF #DB1 CALLBACK ON WITH LOCAL SECURITY #DB2 CALLBACK ON WITH NO LOCAL SECURITY $EB0 DISABLE 11 BIT $EB1 ENABLE 11 BIT #F0 ONLINE FALLBACK DISABLED #F1 ONLINE FALLBACK ENABLED #L0 NEGOTIATES V.42 MODE (MNP OR LAPM) #L1 MNP ONLY #L2 LAPM ONLY #L3 LAPM PROTOCOL PHASE ONLY #P0 NO PARITY WHEN USING 11 BIT ($EB1) #P1 ODD PARITY WHEN USING 11 BIT ($EB1) #P2 EVEN PARITY WHEN USING 11 BIT ($EB1) HIT ANY KEY TO CONTINUE #T0 DISABLE TRELLIS ENCODING #T1 ENABLE TRELLIS ENCODING $V0 ENABLE V.25BIS $V1 DISABLE V.25BIS $VD0 DISABLE VOICE/DATA DIALING $VD1 ENABLE VOICE/DATA DIALING &X0 INTERNAL CLOCKING (SYNC MODE) &X1 EXTERNAL CLOCKING (SYNC MODE) &X2 SLAVE CLOCKING (SYNC MODE) FOR MORE DETAILS REGARDING CALLBACK AND REMOTE CONFIGURATION, PLEASE CONSULT YOUR MANUAL OR MANUAL UPDATE $A0 &A0 #A0 &B0 &BS1 &C1 $D0 &D2 #DB0 $EB0 #F2 $F0 &G0 #L0 $MI0 &M0 &P0 #P2 &Q0 &Q2 $R1 &R1 &RF1 &S1 $SP0 &SF0 %S0 #T1 $V0 $VD0 &X0 Y0 OK REGISTER UNIT RANGE DEFAULT DESCRIPTION S0 1 RING 0-255 1 SETS NUMBER OF RINGS UNTIL ANSWER S1 1 RING 0-255 0 COUNTS RINGS WHICH HAVE OCCURRED S2 ASCII 0-127 43 SETS ESCAPE CODE CHARACTER (+) S3 ASCII 0-127 13 SETS CHARACTER USED FOR RETURN S4 ASCII 0-127 10 SETS CHARACTER USED FOR LINE FEED S5 ASCII 0-127 8 SETS CHARACTER USED FOR BACK SPACE S6 1 SECOND 2-255 2 SETS WAIT TIME FOR DIALTONE S7 1 SECOND 1-255 30 WAIT FOR CARRIER ABORT TIME S8 1 SECOND 1-255 2 PAUSE TIME FOR COMMA S9 100 MS 0-255 6 CARRIER DETECT RESPONSE TIME S10 100 MS 0-255 7 LOSS OF CARRIER DISCONNECT TIME S11 1 MS 1-255 70 TOUCH TONE DURATION AND SPACING S12 20 MS 0-255 50 ESCAPE CODE GUARD TIME S24 50 MS 0-255 20 DROP TIME FOR &C2,&R2,&S2 S25 100 MS 0-255 0 DTR DROP TIME (0 = 50 MS) S30 1 MINUTE 0-255 0 INACTIVITY TIMER (0 = OFF) S0 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S24 S25 S30 000 043 013 010 008 002 045 002 006 007 070 050 020 000 000 OK ERROR B1 E0 M1 Q0 R0 V1 X1 &E1 &E4 &E7 &E8 &E10 &E13 &E15 $MB14400 $SB38400 $BA0 &W0 OK S0 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S24 S25 S30 000 043 013 010 008 002 045 002 006 007 070 050 020 000 000 OK $A0 &A0 #A0 &B0 &BS1 &C1 $D0 &D2 #DB0 $EB0 #F2 $F0 &G0 #L0 $MI0 &M0 &P0 #P2 &Q0 &Q2 $R1 &R1 &RF1 &S1 $SP0 &SF0 %S0 #T1 $V0 $VD0 &X0 Y0 $MB14400 $SB38400 $BA0 &W0 OK OK 0 MODEM 1 2 3 4 5 6 7 8 9 ERROR 0 MODEM 1 2 3 4 5 6 7 8 9 ERROR